Smart PLC Intelligent PLC System
What is smartPLC??
Intelligent PLC system combines all functions into one device for easy and efficient operation!
- 1 Machine size: Height 164 × Width 56 × Depth 165 mm.
- 2 Built-in power supply DC24V / 84W
- 3 inputs 21 points / 21 outputs
- 4 pulse outputs, 2 axes (positioning)
- 5 analog inputs, 2 points (thermocouple/load cell)
- 6 relay output 1 point (AC250V 10A max)
- 7 SD slots and built-in LAN
- 8 digit 2 line LCD screen
Product highlights
- Compact size: Reduces control cabinet size by up to 90%.
- Easy to install: Special mounting bracket, attaches directly to the machine.
- Easy to use: Suitable for all levels of users.
- Complete functions: All the functions necessary for small machines are included in one machine.
-
Reduce complexity: Simple design, quick assembly, and reduced work steps.
- No need to build a control cabinet
- No complicated wiring required (connected via e-CON connector)
- Can directly drive DC solenoid valves (up to 400 mA)
- All I/O points do not need to be connected to common.
-
Flexibility: Customize the program to meet your needs.
- Download Ladder software for free
- The created program can be simply placed into the smartPLC and the file can be transferred.
- Connect the computer via a mini USB cable.
- Support changing programs from SD card
- The file is in Text data format.

📘 Download the manual
| File name | Download link |
|---|---|
| EN (English) | |
| User's Manual | Click here |
| FS Ladder Tool Manual | Click here |
| JP (日本語) | |
| User's Manual (操作マニュアル) | Click here |
| Standard Manual | Click here |
| FS Ladder Tool Manual (日本語) | Click here |
| Warranty (保証書) | Click here |
💻 Download software
| Program name | Download link |
|---|---|
| Data Memory Setting Application | Click here |
| USB Driver (mbed driver) | Click here |
| FS Ladder Application | Click here |
SP303 model information
1. Components and functions
| number | Section name | Description |
|---|---|---|
| ① | Display | Displays various settings and current values. |
| ② | General function buttons | Command buttons, their functions will change according to the program. |
| 3. | RUN-STOP switch | Use to toggle between RUN and STOP modes. |
| ④ | SD channel | For inserting SD cards |
| ⑤ | Main power switch | Use to turn on/off the main unit. |
| ⑥ | Volume knob | Enter the analog numeric values according to the program settings. |
| ⑦ | USB port | Used to connect to a computer |
| ⑧ | e-CON1 connector, common input | For receiving 12 input signals at the back of the device |
| ⑨ | e-CON2 connector common output | For sending 12 output signal points at the back of the machine. |
| ⑩ | LAN port | For connecting to LAN systems |
| ⑪ | AC power connector | For receiving the main power input of the machine |
| ⑫ | fuse box | For inserting fuses to protect against overvoltage. |
| ⑬ | Load cell connector | For bridge type load cells |
| ⑭ | Thermocouple connector | For connecting temperature sensors (K type) |
| ⑮ | Power connector plinth | For external power supply (DC24V) and output control power (voltage equal to input power) |
| ⑯ | e-CON3 connector general input | For receiving signals from 4 points within the device |
| ⑰ | e-CON4 connector general output | For transmitting signals to 4 points within the device |
| ⑱ | e-CON5 connector general input/output | For 1 input and 1 output signal |
| ⑲ | High-speed input connector | For receiving high-speed pulse signals |
| ⑳ | High-speed output connector | For transmitting position control pulse signals |
| ㉑ | Service power supply (+5V) | Used for 5V motor driver interface. |
| ㉒ | Expansion holes | 16mm hole for installing switches or additional devices. |
| ㉓ | e-CON6 connector controls 24V output. | For controlling 24V output signal |
2. Specifications Model SP303
| Input voltage (AC) | AC100~240V 50/60Hz |
|---|---|
| Acceptable pressure range | AC85-264V |
| Power consumption | Not more than 100W (excluding external devices that use AC power) |
| Operating temperature | 10~50℃ |
| Output voltage | Service Power: DC24V ±10% (3.5A) ※ Including internal use and use at 5V DC5V ±10% (1.2A) ※ Including internal use AC Control Power Output: According to the input AC voltage – AC125V or lower: 10A – AC126V and above: 3A |
| Storage temperature | 0~75℃ |
| Humidity during use | 10~90% RH (no condensation) |
| Operating environment | There must be no excessive dust or corrosive gas, and the dust must not be electrically conductive. |
| How to install | Left-side bracket mounting |
| External dimensions | Height 164 × Width 56 × Depth 165 (mm) |
| weight | 1.2 kg. |
3. Performance specifications
| Control system | Stored Program Control Method |
|---|---|
| Input/Output Control Method | Cycle Scan Refresh Method |
| Programming language | Simplified Ladder Mnemonic Language |
| Program capacity | 3,000 steps |
| Display | 2-line × 8-digit LCD with backlight |
| General control buttons | 4 buttons on the front panel [X200~X203] |
| Volume knob | 3 buttons on the front panel |
| Permanent storage | Built-in Flash Memory |
| Data retention during power outages | Store data in DM and CM areas |
| Total number of I/O points | 42 points |
| General DC input | 17 points (DC24V, NPN type) [X000~X015, X204] |
| General DC output | 17 points (DC24V, NPN transistor) [Y000~Y015, Y200] |
| High speed DC input | 4 points (DC24V, NPN type) [X100~X103] |
| High speed DC output | 4 points (DC24V, NPN transistor) [Y100~Y103] |
| Thermocouple input | 1 point, K type, measurable temperature range 0~700℃ |
| Load cell input | 1 point, bridge type |
| AC controlled power supply output | 1 point relay [Y201] |
| DC controlled power supply output | 24V output terminal [Y202] DC24V power supply terminal and input terminal will be powered all the time. |
| Internal auxiliary relay | 800 points |
| Internal state relay | 160 points |
| Timer Relays | 100 points |
| Counter Relays | 100 points |
| Data Memory | 1,700 points |
| Temporary Memory | 100 points |
| Control Memory | 10 points |
| Communication | Support Modbus TCP |
4. General input/output specifications
▶ DC general input – X000~X015 (16 points)
| Input Type | Open Collector Input |
|---|---|
| Input Voltage | DC24V |
| Input Impedance | 4.7kΩ |
| Input Current | 4.8mA |
▶ DC general output – Y000~Y015 (16 points)
| Output Type | NPN Transistor (NPN Transistor Output) |
|---|---|
| Rated Load | DC24V, 400mA |
5. High-speed input specifications
▶ DC high speed input – X100~X103(4 points)
| Input Type | Open Collector Input |
|---|---|
| Input Voltage | DC24V |
| Input Impedance | 4.7kΩ |
| Input Current | 4.8mA |
| Maximum Frequency | 3.8kHz |
▶ DC high speed output – Y100~Y103(4 points)
| Output Type | NPN Transistor (NPN Transistor Output) |
|---|---|
| Rated Load | DC24V, 100mA |
| Pulse Output | Up to 50kHz |
Note: Up to 2 motor positioning axes can be controlled.
+5V power supply is used for motor driver.
6. Thermocouple Input Specifications
▶ Analog input from thermocouple – 1 point
| Input Sensor Type | K-Type Thermocouple |
|---|---|
| Sampling Period | Every 0.2 seconds |
| Heater Output | AC control output (Y201) |
| Control Method | ON/OFF Control |
| Measurement Range | 0~700℃(±2℃) |
▶ Analog input from load cell – 1 point
| Excitation Voltage | DC5V ±5% |
|---|---|
| Resolution | 24 bit |
| Maximum Rated Input Range | 1-3 mV/V |
| Measurement Range | 0-500 kilograms |
| Temperature Drift | ±10 nV/℃ |
7. Specifications of the power connector (Terminal Block)
▶ DC24V Service Power
| Rated Voltage | DC24V ±10% |
|---|---|
| Rated Current | 3.5A (including internal power consumption) |
▶ AC Power Control Output
| Rated Voltage | According to the main unit voltage (AC100~240V) |
|---|---|
| Rated Current | Depending on the main unit voltage: – 10A at 100V – 3A at 240V |
8. Expansion I/O Specifications
▶ DC General Input Extended – X204
| Input Type | Open Collector Input |
|---|---|
| Input Voltage | DC24V |
| Input Impedance | 4.7kΩ |
| Input Current | 4.8mA |
▶ DC general output extended – Y200
| Output Type | NPN Transistor (NPN Transistor Output) |
|---|---|
| Rated Load | DC24V, 400mA |
Q&A Frequently Asked Questions
Can I increase the number of I/O points using a Modbus/TCP-compatible DIO Unit?
▶
A: smartPLC only supports server functions, so you cannot increase the number of I/O points using DIO Unit, etc.
If the number of input/output points is insufficient, can it be expanded using expansion units from other companies?
▶
A: You cannot use expansion units from other companies.
In addition to the input/output on the back of the smartPLC, numbers ⑱, ⑲, and ⑳ can also be used as input/output.
(*Note: Connectors ⑲ and ⑳ are not E-CON type connectors.)
In addition to the input/output on the back of the smartPLC, numbers ⑱, ⑲, and ⑳ can also be used as input/output.
(*Note: Connectors ⑲ and ⑳ are not E-CON type connectors.)
Does it have an analog input/output function?
▶
A : There is no analog input/output function.
Only K-type thermocouples and load cells can be connected.
Only K-type thermocouples and load cells can be connected.
Please inform the rated load of the general output.
▶
A : The rated load is DC24V 400mA.
For safety reasons, can an Emergency Stop button or Area Sensor be used to shut off the power to the output side?
▶
A: Inside the smartPLC, there is a connector called “Power Control 24V Output E-CONS (E-CON6)” for controlling 24V power. If an Emergency Stop button is connected to this section, the 24V power supply can be directly cut off via hardware.
Is there a circuit protector function inside the device to protect the external input/output circuit?
▶
A : Yes - There is a fuse inside the electrical circuit which will automatically cut off the circuit when the current flows over 10A.
Please explain about LAN communication.
▶
A: It can control up to 2 devices simultaneously through a Hub connection.
Please explain about the internal processing speed.
▶
A: It is usually between 1 ms and 10 ms, but it will vary depending on the length of the program and the function being used.
What is the Volume (VR) control button on the front panel used for?
▶
A: It can be used within a Ladder Program by setting a Maximum Value in the program, then the value of the VR button will be stored in an internal register proportional to the set value (Example: VR1's Maximum Value is set to 100).
When VR1 is set to be used for Timer setting, the user can freely adjust the time range between 0.0 and 10.0 seconds without the need to edit the program.
When VR1 is set to be used for Timer setting, the user can freely adjust the time range between 0.0 and 10.0 seconds without the need to edit the program.
Can the PLC's internal auxiliary relay or data memory be controlled from a computer?
▶
A: This can be done using a free logic software provided by the company called “FS_Ladder” which can directly toggle the coil state (On/Off) and edit the numerical values in the registers.
Can programs created with other companies' products be converted to use with smartPLC?
▶
A: It cannot be converted directly. You must convert again by entering the data manually.
How long is the continuous work record?
▶
A: There is continuous usage data for 8 hours per day for 5 years. However, this product is not designed for 24-hour continuous operation.
For further inquiries
You can contact the team directly through the channels below.
📞 Purchasing Department: 062-592-6945
📦 General Department: 020-777-207
💬 LINE ID: @fakiki (Click here)